Power Transformers & Substation Units
CATEGORY 06 TRADITIONAL GRID INFRASTRUCTURE

Power Transformers & Substation Units

10kV – 500kV Oil-Immersed & Dry-Type Units · Low-Loss CRGO Steel · Maschinenfabrik Reinhausen OLTC

Up to 500 kV
Max Voltage Class
Up to 360 MVA
Max Single Unit Rating
< 10 pC
Partial Discharge (FAT)
IEEE / IEC
Dual Standard Compliance
ENGINEERING SPECIFICATION & SUPPLY CHAIN OVERVIEW

Engineering Certainty in Transformers Sourcing

Kingshark Energy exports heavy electrical power transformers manufactured by China's premier state-verified high-voltage substation manufacturing bases. We supply 10kV to 500kV oil-immersed generator step-up (GSU) transformers, transmission auto-transformers, cast resin dry-type distribution units, and pad-mounted substation transformers rated up to 360MVA.

Our power engineers conduct rigorous electrical engineering reviews on tender single-line diagrams (SLD). We verify impedance matching, short-circuit withstand levels, BIL (Basic Lightning Impulse Insulation Level), and harmonic tolerance (K-factor) to ensure seamless synchronization with overseas grid codes (IEC 60076, IEEE C57, ANSI).

Core laminations use high-permeability Cold-Rolled Grain-Oriented (CRGO) silicon steel (Baidu / Baosteel), precision step-lap stacked to minimize no-load losses and acoustic noise. We integrate world-class tap changers (Maschinenfabrik Reinhausen MR, Huaming) and multi-channel online DGA (Dissolved Gas Analysis) monitoring suites.

PRODUCT CLASSIFICATION & MATRIX

Sub-Product Breakdown & Technical Specifications

Every product is drawing-verified and audited to IEEE / IEC international norms.

Up to 360MVA · ONAF / OFAF / ODAF Cooling

110kV – 500kV Oil-Immersed Power Transformers (GSU)

Utility substation backbone units designed for extreme lightning impulse and seismic withstand. Bell-type tank, high-purity oxygen-free copper windings, and high-temperature insulation paper.

Technical Parameters
Voltage Ratings 110kV, 132kV, 138kV, 230kV, 345kV, 500kV
Power Capacity 40MVA to 360MVA (Three-Phase / Single-Phase banks)
Cooling Methods ONAN / ONAF / OFAF / ODAF
Tap Changer MR (Maschinenfabrik Reinhausen) OLTC or On-Load Vacuum
Partial Discharge < 10 pC at 1.5 Um/√3
Class F / H Insulation · Flame Retardant

10kV – 35kV Cast Resin Dry-Type Transformers

Safe, non-flammable units for commercial high-rises, hospitals, data centers, and underground subways. High mechanical strength and zero risk of toxic gas emissions during fire.

Technical Parameters
Capacity Range 100 kVA – 4000 kVA
Primary / Secondary 10kV / 11kV / 20kV / 33kV to 400V/415V/480V
Insulation Class Class F (155°C) or Class H (180°C)
Enclosure Rating IP00, IP20, IP23, IP31 with cooling fan
Certifications C2, E2, F1 certified per IEC 60076-11
Tamper-Proof Enclosure · Underground Loop Feed

Pad-Mounted Distribution Substation Units

Dead-front, tamper-resistant outdoor substation combining MV load-break switches, backup current-limiting fuses, and distribution transformer in a single compact housing.

Technical Parameters
Capacity Options 300 kVA – 2500 kVA
High Voltage Side 12.47kV, 13.8kV, 24.94kV, 34.5kV (Loop/Radial Feed)
Insulating Fluid FR3 Natural Ester (Biodegradable) or Mineral Oil
Tank Construction Stainless Steel Tank (Corrosion resistant)
Standard Compliance IEEE C57.12.26, IEEE C57.12.28 (Tamper-Resistance)
Photoacoustic Spectroscopy (PAS) · Multi-Gas

Online DGA Monitoring & Bushing Diagnostics

Advanced online dissolved gas analysis (DGA) monitoring H2, CO, CO2, CH4, C2H4, C2H2 and moisture in real time, preventing catastrophic dielectric failure.

Technical Parameters
Detectable Gases H2, CO, CO2, CH4, C2H2, C2H4, C2H6, H2O
Detection Limit C2H2 < 0.5 ppm / H2 < 5 ppm
Sampling Interval 1 Hour to 24 Hours programmable
Communication IEC 61850, Modbus TCP, Optical Fiber Ethernet
Bushing Monitoring High-voltage bushing Tan Delta & Capacitance
ZERO INTERFACE DEFECT PROTOCOL

International Compliance & 100% FAT Witness Audit

Complete factory routine and type tests: Lightning impulse test (BIL up to 1550kV), induced overvoltage with partial discharge measurement (< 10pC), temperature rise test, sound level, and short-circuit withstand calculation.

IEC 60076IEEE C57.12.00ANSI C57IEC 60137IEC 60214ISO 9001ISO 14001

Seaworthy Packaging & Port Dispatch

Shanghai · Ningbo · Qingdao Ports

Large units shipped filled with dry nitrogen and fitted with three-axis electronic impact recorders. Heavy-lift low-bed transport to Shanghai and Ningbo deep-water berths for ocean freight.

FOB / CIF / DDP
SGS / BV Witness
MTR & Mill Certs
TECHNICAL INQUIRY & TENDER SUBMISSION

Request Technical Proposal for Transformers

Direct evaluation by Dean and lead power engineers. We respond in under 4 hours.

Direct Chairman Line: +86 13801620868
dean@kingsharkenergy.com
← Prev Category: EV Superchargers All 8 Categories Next Category: Power Cables →